Float Level Switch EX proof DxELS

SKU: dxELS

Manufacturer: Ensim

DX-ELS ex-proof float level switches are used for tank level control.Different connections and material types are available.

download pdf datasheet

Working Principle:

The magnetic field of the magnet in the float that moves along the tube according to the liquid level opens or closes the electrical circuit when the reed is aligned to the sensor. These changes of the reed sensors and alarm or level information can be evaluated by a relay circuit or controller.

 

Application Fields:

ex

Tank level measurement and control,boiler control,tank control.

Yacht water level control, sewage level control.

Hydraulic oil tank level measurement and control.

 dxels applications

Advantages:

  •  A variety of materials according to the flow
  • Different choices of ignition
  • Quick delivery
  • Different types of technics

Specifications:

Working Temperature:Max. 125C , 80C (Plastic Model)
Ambient Humidity:0-98 %Rh (Non-condensing)
Ambient Temperature (Ta):(-) 20 ... (+) 60C
Material/Connection:304 St.st. (Std.) Opt. 316 St.st. , Aluminum
Housing:Aluminium Injection-AISi12Fe (Std)
Black (RAL 9005)
Float:316 St.st. (Std) Opt. PU , PP
Pipe:304 St.st. (Std.) Opt. 316 St.st. , Brass,PVC,PTFE
Connection:2"BSP (Std.) Opt. sel-ectable from Table.
Float Type:S40 (Std.), sel-ectable from Table.
Number of Float:1 (Std.) 
Stem Length:Max. 2500 mm (Thread Included)
Electrical Connection:Terminals
Cable and Plug Entry:M20x1,5 (Std)
Number of contacts:2 x SPST-NA (Std.) Opt. It can be added.
Contact Current:1,5 Amber (Std.)
Max. Contact Current:50 W / VA or 20 W / VA
Max. Supply Voltage:200 VDC / 250 VAC, 30 VDC / 140VAC (Std.) Opt. sel-ectable.
Protection Class:IP 66 (EN60529)
Certifications and Approvals:CE Declaration,EMC,LVD,ATEX