SKU: MID-MDS
Manufacturer: Bopp & Reuther Messtechnik
Our electromagnetic flowmeters are mainly used in the food and beverage industry. They work according to the Faraday principle. Unlike all other electromagnetic flowmeters on the market, they operate in an alternating field (AC) instead of a synchronized DC field. The result is higher measurement dynamics and faster, more precise measurements for dosing the filling time up to 100ms.
Their function is based on conductive liquids (>1µS/cm) in filling machines. These machines are mainly used in the food and beverage industry as well as in the pharmaceutical and fine chemical industries. Among others, dairy products (also with fruit pieces), ketchup, mayonnaise, mustard, sauces, dressings, cleaning and washing agents, medical products (e.g. stomach gels), sterile injection products and cosmetics are measured.
Nominal size | DN10 up to DN40 (3/8“ bis zu 1½“) |
Process connection | Tri-Clamp, hygienic connection for sanitary thread, sterile connections, sterile mini flanges |
Material | stainless steel, PTFE, Hastelloy |
Conductivity | >1µS/cm |
Flow range | 0,25 ms to 10 ms |
Repeatability | ±0.1% (depending on flow rate) |
Process temperature | up to 95°C (203°F) – Cleaning up to 95°C (203°F) |
Prozessdruck | up to 16 bar |
Ex-protection | no |