Dosing System MID-MDS for conductive liquids, Bopp & Reuther

Dosing System MID-MDS conductive liquids

SKU: MID-MDS

Manufacturer: Bopp & Reuther Messtechnik

Modular dosing system (MDS) for filling conductive liquids in filling machines with electromagnetic flowmeters

download pdf datasheet El-Mag FM
download pdf datasheet Controller

Our electromagnetic flowmeters are mainly used in the food and beverage industry. They work according to the Faraday principle. Unlike all other electromagnetic flowmeters on the market, they operate in an alternating field (AC) instead of a synchronized DC field. The result is higher measurement dynamics and faster, more precise measurements for dosing the filling time up to 100ms.

Applications

Their function is based on conductive liquids (>1µS/cm) in filling machines. These machines are mainly used in the food and beverage industry as well as in the pharmaceutical and fine chemical industries. Among others, dairy products (also with fruit pieces), ketchup, mayonnaise, mustard, sauces, dressings, cleaning and washing agents, medical products (e.g. stomach gels), sterile injection products and cosmetics are measured.

Characteristics

  • easy cleaning compared to piston filler
  • easy adjustment of the filling quantities
  • no shear forces are exerted on the product

Special Features

  • shortest dosing times from 100ms possible
  • small dimensions of the sensor
  • Complete systems for linear and rotary fillers
  • Large range of filling quantities with different nominal diameters
  • direct control of the dosing valve
  • CIP / SIP Cleaning
  • Replacement of the flow sensor possible without reprogramming

Batch Controller

  • MID-MDS system for filling control (measurement and valves)
  • up to 540 electromagnetic measuring instruments MID and valves
  • with communication interface RS232 for communication with the PLC
  • MDS terminal for configuration and visualization of the MID-MDS system
  • UV 14 converter module for use of user-defined PLC
  • MID-PLC for the construction of small filling machines up to 4 devices and 4 valves

Technical data

Nominal size DN10 up to DN40 (3/8“ bis zu 1½“)
Process connection Tri-Clamp, hygienic connection for sanitary thread, sterile connections, sterile mini flanges
Material stainless steel, PTFE, Hastelloy
Conductivity >1µS/cm
Flow range 0,25 ms to 10 ms
Repeatability ±0.1% (depending on flow rate)
Process temperature up to 95°C (203°F) – Cleaning up to 95°C (203°F)
Prozessdruck up to 16 bar
Ex-protection no