To avoid measuring errors that result from air or gas contained in liquids measured with volumetric and mass flow meters. download pdf datasheet
The field of application of the MDS-PLC is the control of meters and valves in small filling machines. The MDS-PLC configures the parameters and settings, visualizes the data and controls the valves. download pdf datasheet
The compact orifice Oriflow is used for flow measurements of conductive and non-conductive fluids, gases and vapours in all industrial branches. The PVDF Oriflow model is custom made for HCL Hydrogen Clorine gas and highly corrosive media. download pdf datasheet
Mass flow meters dedicated to the measurement of liquids and gases. Applications: Custody transfer for mineral oils, bitumen and other viscous media - Process measurement of mechanical and plant engineering download pdf datasheet
The liquid density meter of the DIMF series is used for continuous measurement of the density/concentration of liquids or liquid mixtures. The proven tuning fork principle guarantees a high acccuracy with very good long term stability.The robust design ensures reliable operation even under harsh operating conditions. download pdf datasheet
The dosing mass flow meter extends the range of dosing sensors with a special focus on the dosing of non-conductive media and direct mass dosing. download pdf datasheet FMD Massflow Meter download pdf datasheet MDS Controller
Modular dosing system (MDS) for filling conductive liquids in filling machines with electromagnetic flowmeters download pdf datasheet El-Mag FM download pdf datasheet Controller
Compact magnetic inductive flowmeter for filling conductive liquids in filling machines download pdf datasheet El-Mag FM download pdf datasheet Controller
The focus is on the measurement of non-conductive liquids. This meter is designed for the measurement of e.g. oil or demineralized water. Due to the measuring principle, an inlet or outlet section is not required. download pdf datasheet OD Flow Meter download pdf datasheet MDS Controller
The field of application for all electromagnetic flowmeters of the SpiraMAG® series is the measurement of conductive liquids (>5µS/cm) like water, waste water in continuous flow measurement. The series comprises the nominal diameters DN 15 to DN 1000 and is available in the pressure stages PN 10/16/40. The standard maximum temperature is 60°C. download pdf datasheet
The UR-06 is used for the acquisition, display and output of mass and volume flows, including the calculation of net values for standard conditions. The integrated batch function allows the UR06 to acquire batches via external signals and store them in the original document memory. Plug-in modules allow the connection of different sensor systems for the acquisition of mass flow, pressure, temperature or density. download pdf datasheet
The URS-06 can be used for simple dosing tasks. Pumps and valves can be controlled. Operation is via a 3.5 inch touch screen with integrated PLC. This allows the operator to make all the necessary entries for dosing. download pdf datasheet
The URS-09 can be used for more extensive dosing tasks and loading systems. Pumps, valves, etc. can be controlled. Operation is via a 5.7-inch touch screen with integrated PLC. This allows the operator to make all the necessary entries for dosing. download pdf datasheet
Versatile flowmeter for measuring the volume of liquids in mechanical engineering, factory automation and process instrumentation, such as suited for industrial fluids, chemical fluids, mineral oils and fuels. The modular design combines reliable mechanical sensors with modern electronics. The plastic version is suitable for measuring the volume of corrosive liquids, acids, alkalis, solvents, dyes… download pdf datasheet
Oval Wheel Meters Type OaP are used for measuring liquid raw, intermediate and finished products such as liquefied gases, gasolines, heating oils, lubricating oils, transmission oils, solvents, bitumen, alkaline solutions, acids and other chemical liquids: double case - high accuracy - custody transfer - SIL2 approval download pdf datasheet
The focus is on the measurement of non-conductive liquids. This meter is designed for the measurement of e.g. oil or demineralized water. Due to the measuring principle, an inlet or outlet section is not required. download pdf datasheet
Oval wheel meters type OI are used for the measurement of liquid products such as liquefied gases, acids, alkaline solutions, fats, alcohols, solvents, dispersions, polymers, poly-condensates, paints, colors and adhesives, 0.2 -1,200 l/min, accuracy up to ±0,1% download pdf datasheet OI Flowmeter download pdf datasheet Counter
Oval wheel meters type OP are used for measuring mid to high viscosity liquids such as gasolines, heating oils, lubricating oils, diesel oil, bio ethanol and some chemical liquids. download pdf datasheet
To avoid measuring errors and damage caused by solid particles contained in the fluid. download pdf datasheet
The turbine meter is used for flow and volume measurement of liquids and liquefied gases in the chemical and petrochemical industry, in the mineral oil industry and loading systems, especially for high operating pressures and low viscosities: crude oil, mineral oil, acids, alkaline solutions, solvents, water, liquefied gases, refined oil products (gasoline, kerosene, jet A1, JP8, diesel), vinyl chloride download pdf datasheet
The VTX vortex meter is used for flow and volumetric measurements of conductive and non-conductive fluids, gases, vapours, saturated and superheated steam in all industrial branches: integrated pressure & temperature compensation - heat quantity measurement of steam and hot water - consumption measurement in compressed air networks download pdf datasheet