Dosing System OD for non-conductive liquids, Bopp & Reuther

Dosing System OD non-conductive liquids

SKU: OD

Manufacturer: Bopp & Reuther Messtechnik

The focus is on the measurement of non-conductive liquids. This meter is designed for the measurement of e.g. oil or demineralized water. Due to the measuring principle, an inlet or outlet section is not required.

download pdf datasheet OD Flow Meter
download pdf datasheet MDS Controller

Characteristics

  • direct measurement of volume
  • measurement of non-conductive and conductive liquids
  • high accuracy / repeatability also for small quantities
  • high long-term stability

Special Features

  • Fillings from 10 ml possible
  • very short dosing times > 250ms
  • high resolution (e.g. DN10: 2000 pulses/l)
  • large selection of filling quantities with different nominal sizes
  • can be combined with the batch controller

Technical data

Nominal size DN10,DN15,DN25
Process connection TriClamp according to DIN 32676
Material

Housing: stainless steell

Oval wheels: stainless steel, PEEK

Seals: EPDM, alternatively Viton

Flow Range

0.2 l/min to 5 l/min  –  2,000 Pulses/

(0.05 gal/min to 1.32 gal/min)l

1 l/min to 30 l/min  –  1,000 Pulses/l

(0.26 gal/min to 7.93 gal/min)

2 l/min to 50 l/min – 400 Pulses/l

(0.53 gal/min to 13.21 gal/min)

4 l/min to 100 l/min – 200 Pulses/l

Accuracy ±0,25% to ±0,5%
Repeatability ±0,1%
Viscosity 0,3 to 1.500 mPa·s
Process temperature

Liquid temperature: -10°C to +130°C
(-14°F to 266°F)

ambient temperature: -20°C to +70°C
(-4°F to 158°F)

Process pressure max. 16 bar
Ex-protection
no