SKU: TA DI
Manufacturer: Hoentzsch
Inline sensors / Measuring tubes
Thermal measuring tubes TA Di are suitable for measuring the standard flow rate / mass flow of gases and have standard inside diameters of 8; 16; 21.6; 27.2; 35.9 and 41.8 mm.
The transducer U10b is integrated or separate and delivers a standard flow rate-proportional analog signal and quantity pulse.
Mechanical connection with imperial pipe threads.
onfigurable via an optional keypad in the housing lid or via WiFi interface.
Types:
with integrated tranducer - with separate evaluation unit - explosion proof
Models:
Insertion Probe | Measuring tube | fixed evaluation unit | portable evaluation unit | Software |
Standard flow velocity [Sm/s],
Standard flow rate [Sm³/h] or [Sl/min],
Mass flow rate [kg/h],
Standard volume [Sm³],
Temperature [° C, ° F].
With optional M-Bus: standard flow rate, mass flow rate, standard volume.