Centec Process System Pure Steam Generation for Sterilization

Pure Steam Generation

SKU: PureSteam

Manufacturer: Centec

Pure Steam Generation for Sterilization of Tanks, Pipes, Machines

download pdf datasheet

PureSteam

Application

Pure steam is used for sterilization of tanks, pipeworks and filling machines. The pure steam generator PureSteam produces sterile, pyrogen-free steam that is ideally suited for SIP (Sterilization-in-Place). The system can also be designed for the production of clean steam for direct injection into the product.

Description

For pure steam generation the feed water enters a tubular heat exchanger with an expansion chamber above. In the tubular heat exchanger the pre-treated water is heated and steam is generated. The tubes of the heat exchanger are connected with the expansion chamber that serves as a separating column. For production of pyrogen-free steam the chamber contains a demistor. After entering the expansion chamber, the steam moves further upwards in the column. By gravity and due to the specific column design, unevaporated water droplets fall back into the lower section of the chamber, thus separating from the steam. Since the droplets may contain contaminants like endotoxins, it is vital that they are not carried forward with the steam. As an important quality characteristics, the conductivity of the pure steam condensate can optionally be monitored. If required, the pure steam generator can be enlarged by additional columns to build up a multi effect distillation system. This allows combined generation of pure water and pure steam at the same time.

  • Generation of sterile, pyrogen-free steam
  • Extension to a multi effect distillation system possible
  • Distribution of pure steam for SIP applications on demand
  • Customized modular design with a standard PLC
  • Skid mounted for easy installation and start-up

Typical Technical Data

Capacity 50 - 15.000 kg/h
Steam Pressure max. 7 bar
Steam Temperature up to 165 °C
Endotoxins < 0,25 EU/ml
Material according to requirements (1.4404, 1.4435/AISI 316L, …)
Heating Medium steam, electric heating
Options different automation levels; remote maintenance access; water pre-treatment; conductivity measurement in the condensate; combined pure water generation; pure steam distribution (loop)