Products
Temperature transmitter is an integral element of temperature sensor, available also as a separate component. It converts temperature sensor signal to analogue 4÷20mA, voltage 0÷10V or different signal. Transmitter can be placed directly on TS-35mm rail. Temperature range: -200÷1820º C download pdf datasheet
Temperature transmitter is an integral element of temperature sensor, available also as a separate component. It converts temperature sensor signal to analogue 4÷20mA, voltage 0÷10V or different signal. Transmitter can be placed directly in connection head or on TS-35mm rail. Temperature range: -200÷1820º C download pdf datasheet
Temperature transmitter is an integral element of temperature sensor, available also as a separate component. It converts temperature sensor signal to analogue 4÷20mA, voltage 0÷10V or different signal. Transmitter can be placed directly in connection head or on TS-35mm rail. Temperature range: -270÷1820º C download pdf datasheet
Tubes for high pressure, heat resistant and creep resistant steel tubes, ceramic and special tubes, threaded tubes or suitable for welding, mounting connections Max temperature upto 1800º C download pdf datasheet
Connection heads are integral elements of temperature sensors, available also as separate components. They are made primarily of aluminium alloys, but stainless steel, polyamide or noryl heads are also available. Wide range of connection heads allows head selection according to client requirements and application specifications. download pdf datasheet
Connection heads are integral elements of temperature sensors, available also as separate components. They are made primarily of aluminium alloys, but stainless steel, polyamide or noryl heads are also available. Wide range of connection heads allows head selection according to client requirements and application specifications. download pdf datasheet
Connection heads are integral elements of temperature sensors, available also as separate components. They are made primarily of aluminium alloys, but stainless steel, polyamide or noryl heads are also available. Wide range of connection heads allows head selection according to client requirements and application specifications. download pdf datasheet
Flameproof Connection heads are integral elements of temperature sensors, available also as separate components. They are made primarily of aluminium alloys, but stainless steel, polyamide or noryl heads are also available. Wide range of connection heads allows head selection according to client requirements and application specifications. download pdf datasheet
AirGate-Modbus is a wireless multifunctional gateway that allows the transparent and easy insertion of wireless branches into existing wired RS485 networks. The AirGate-Modbus has four operation modes, Modbus Master, multiplexer, USB RS485 converter and simple wireless RS485 extension. A proprietary protocol based on IEEE 802.15.4 facilitates operation in star mode, allowing the connection of several wireless segments to an existing Modbus RS-485 network. download pdf datasheet
OS-3protection tube is used with temperature sensor as a replaceable component of the part that deteriorates the most often. It is made of acid-resistant steel. Selection of parameters and design depends on sensor requirements. download pdf datasheet
OS-1 or 2 protection tube is used with temperature sensor as a replaceable component of the part that deteriorates the most often. It is made of acid-resistant steel. Selection of parameters and design depends on sensor requirements. download pdf datasheet
OS-4 protection tube is used with temperature sensor as a replaceable component of the part that deteriorates the most often. It is made of acid-resistant steel. Selection of parameters and design depends on sensor requirements. download pdf datasheet
Ceramic protection tubes are suitable for applications with high operating temperatures, replacing standard steel thermowells. Protection tubes are replaceable elements and their selection depends primarily on ambient conditions, operating temperature and measured medium. download pdf datasheet
OG protection tube is a part of measuring installation, where a sensing element (temperature sensor) is installed by means of a set screw. Protection tube is mounted by means of a threaded connector. It is manufactured in accordance with individual client requirements. download pdf datasheet
OGG protection tube is a part of measuring installation, where a sensing element (temperature sensor) is installed by means of a threaded connector. Protection tube is mounted by means of a threaded connector with a male thread. It is manufactured in accordance with individual client requirements. download pdf datasheet
OSG protection tube is a part of measuring installation, where a sensing element (temperature sensor) is installed by means of a threaded connector. Protection tube needs to be welded. It is manufactured in accordance with individual client requirements. download pdf datasheet
OTG protection tube is a part of measuring installation, where a sensing element (temperature sensor) is installed by means of a threaded connector. Protection tube is mounted by means of flange. It is manufactured in accordance with individual client requirements. download pdf datasheet
Drilled thermowells for use in high pressure and high flow, as security for the proper operation of RTD and TC sensors (ex. type TOPGI-11) in measurement applications. The whole element is made of a single material with a deep drilling over the entire length. They are widely used in heavy industry, food, chemical and power industry. The thermowell is screwing in a place of measurement via threaded connector. Barstock download pdf datasheet
Drilled thermowells for use in high pressure and high flow, as security for the proper operation of RTD and TC sensors (ex. type TOPGI-11) in measurement applications. The whole element is made of a single material with a deep drilling over the entire length. They are widely used in heavy industry, food, chemical and power industry. Weld-in thermowells are welded directly into the measurement process.High pressure resistant thermowell for welding SWS-P, SWS-Z, SWS-S, SWS-SZ. Barstock download pdf datasheet
Drilled thermowells for use in high pressure and high flow, as security for the proper operation of RTD and TC sensors (ex. type TOPGI-11) in measurement applications. The whole element is made of a single material with a deep drilling over the entire length. They are widely used in heavy industry, food, chemical and power industry. The thermowell is mountable via flange. Barstock download pdf datasheet
The head-mounted LPI digital display is an integral element of temperature sensor, available also as a separate component. It enables local indication of temperature measured directly in connection head. It has 3 configuration keys at the front panel.
Field Loggeris a compact videographic recorder with analogue and digital inputs. 24 bit A/D converter allows reaching high resolution and operating speed even to 1000 samples per second. It has 8 programmable inputs, suitable for thermocouple sensors, RTD sensors and current and voltage signals. It has two alarm relays and 8 additional channels programmable individually as inputs or outputs. The recorder can have 128 virtual channels according to mathematical and logical functions, and 32 alarm events that can activate outputs, send messages in form of e-mails or control the process of recording. Field Logger has two USB interfaces – one for configuration via PC and the other for data downloading from the flash memory. Data are registered on inner memory 512kB or on SD card slot suitable for cards up to 16GB. Recording on PC is realized via RS485 interface (master/slave) operating in Modbus RTU or Ethernet 10/100Mbps, which enables an access to recorder via WWW (HTTP) web browser, FTP (client and server), SMTP (e-mail sending), SNMP and Modbus TCP. download PDF
The most popular Limatherm Sensor temperature controller. It has a universal input suitable for most common thermocouple sensor as well as Pt100. Low or standard 230V power supply can be selected. Up to 3 outputs programmed as alarm or control outputs, including SSR or 4÷20mA (control) output. Two displays: upper red colour presents temperature of process; lower green colour presents set temperature. Black enclosure, anti-reflection coating and clear indication. Degree of protection of front panel IP65. There is a possibility to block the access to specified parameters via software as well as device blocking by means of jumper.
The large Limatherm Sensor temperature controller N960 has a universal input suitable for most common thermocouple sensor as well as Pt100. Low or standard 230V power supply can be selected. Up to 3 outputs programmed as alarm or control outputs, 3 universal outputs including SSR 14V for control of three-phase semiconductor relays or 4÷20mA (control or retransmission). Two displays: upper red colour presents temperature of process; lower green colour presents set temperature. Black enclosure, anti-reflection coating and clear indication. Degree of protection of front panel IP65. There is a possibility to block the access to specified parameters via software. download PDF
Universal digital display N1500. Power 230 or 24 V. The standard two independent relay NC / NO. Display in housing with protection against reflections black, red numbers. Additional options: extension for a further 2 independent relay outputs NO, the output current of 4-20 mA retransmission, communication module RS-485 MODBUS.
LoopView is a two-wire (4 ÷ 20) mA loop indicator, loop powered and low power. Its excellent precision allows to indicate several measurements like pressure, differential pressure, flow, pH, temperature, acceleration and other. It has valve type connector standard EN 175301-803 (old DIN 43650) male and female. LoopView is powered by the current loop itself and allows to be inserted into sensors already installed in industrial facilities, with same connector type.
TxBlock USB is a head mounted temperature transmitter. It has universal inputs for thermocouples J, K, T, E, N, R, S, B, Pt100, Pt1000, 0÷50 mV and thermistors NTC 10kΩ. Transmitter output can be programmed as 4÷20 mA or 20÷4 mA. Configuration with transmitter is done using free software TxConfig II and a standard micro USB cable. This solution eliminates the need to use special and expensive configurators. Temperature range: -270÷1820º C download pdf datasheet
2, 3-point or continuous temperature controller for Pt100, Pt1000, thermocouples, voltage / current, DI. PID with autotuning. Programmable measuring range and alarm functions.
2, 3-point or continuous temperature controller for Pt100, Pt1000, thermocouples, voltage / current, DI. PID with autotuning. Programmable measuring range and alarm functions.
2, 3-point or continuous temperature controller for Pt100, Pt1000, thermocouples, voltage / current, DI. PID with autotuning. Programmable measuring range and alarm functions.
The DL TagTemp Stick is an electronic temperature recorder. An internal sensor measures the temperature and the read value is stored in memory. This data of up to 32000 temperature values can later be downloaded to a computer for display and analysis in the form of tables or charts. download PDF
The compact data logger DL-TagTemp-NFC with external temperature sensor is ideal for temperature monitoring in cooling transport boxes and refrigerators. Data can be downloaded via wireless NFC protocol using either a smartphone or a PC. The full-featured, portable data logger has a sealed housing with IP68 protection. It is powered by a non-replaceable battery that lasts up to 1 year download PDF
The DL-TagTemp-NFC-LCD is a portable temperature recorder with integrated display via a mini LCD display. The more than 4,000 temperature data recorded in the unit's internal memory can be accessed via smartphone with NFC interface or via USB connection on a computer. The replaceable lithium battery has a runtime of up to 2 years (30 min acquisition interval). download PDF
The DL-ToolBox 4.0 from Mülller IE is the suitable tool for remote monitoring of gensets and plants. Using a web app and software, machine data is digitized and monitored, thereby reducing operating and maintenance costs. Remote diagnosis is possible using intuitive evaluation software on smartphone, PC and data cloud. download PDF