The low-cost device in PVC is frequently used in water technology. The device in PVDF is suitable for the flow measurement of aggressive media, e.g. in water treatment, while the DST-1/2 is mainly used for flow measurement of air and gases.
The measuring range extends from 0.02 - 0.16 m3/h to 300 - 1800 m3/h for H20, and from 0.15 m3/h - 1.5 to 1200 - 6000 m3/h for air at STP.
The DST bypass flow meter operates on the differential-pressure-bypass method. A ring with an orifice plate is installed in the pipeline between flanges. The measuring orifice leads to a constriction and causes a differential pressure. As compensation a volume flow occurs in the bypass which is displayed by a variable area flow meter. This partial flow is proportional to the flow rate in the main pipeline.The unimpeded, straight tube length has to be 6DN before and 4 DN behind the mounting position. The partial flow can be turned on and off, as required, by installing two ball valves in the bypass line.