dxecap113

Capacitance Level Transmitter EX

SKU: dx ecap

Manufacturer: Ensim

The DX-ECAP level transmitter is a capacitive level sensor for level measurement of conductive liquid, non-conductive liquid, granulated materials with solid particles, adhesive and acid/basic liquids

download pdf datasheet

When a material comes between electrode rod and tank wall, a capacitance change occurs andwhen this change exceed adjustment threshold, contact output is delivered. Designed for difficult process conditions. Refrigerated modelscan be manufactured for high temperature and pressure conditions. Calibrations of triggering point and relay operation range can be performedby the user under workplace conditions. It can be connected horizontally or vertically.

Aplications:ex

Liquid tanks, food machines, cooling liquid tanks, shipping, glycol tanks, brine,waste water tanks.Oil tanks, CO2 liquid tanks, high temperature tanks, non-conductive liquids.Grain stores, cement, sand feed, flour, milk powder, organic and plastic granule.Sticky hot and high viscosity liquid, acid and chemical liquids

DXapplication

Advantages:

  • no moving parts
  • high pressure and temperature design
  • modular structure with easy assembly
  • not affected by foam, liquid splashes
  • not affected by vibration, has robust mechanical structure
  • zero span adjustment is easy
  • measurement along whole sensor
  • operability with reverse assembly

 

Models for:

  • Conductive Liquids
  • Low Conductive Liquids
  • Solid particulate materials
  • Adhesive and acid/basic liquids

Supply:9-36 VDC
Signal Output:4-20mA two wire Std.
0-20mA-4-20mA,0-01 V Three wire Opt.
Accuracy: +%0,5, +%0,8,4%1
Linearity:%0,5
Capacity Range:1pF...3nF
Min. Di-Electric Constant:1,6
Connection Material:304 St.st. opt. 316 St.st.
Isolation Material:PFA Std. Opt. PEEK,PTFE,Rubber,FKM
Housing Material:Aluminum Injection Molding-AISi12Fe (Std)
Black(RAL9005)
Working Presure:(-)1...25 bar (Depending on the model.)
Working Teperature:(-)40 / (+) 150C (Depending on the model.)
200C with cooling apparatus
(-) 196C For Cryogenic Tank
(-) 50...+80C For NBR
FKM(-)50...+80C For NBR
FKM (-)30...+200C
Ambient Temperature:(-)20 / (+) 60C
Display:With LED-Power and Contact LED
Isolation:Max. 500mW
Power Consumption:.Max. 50mW
Electrical Connection:Terminal
Protection Class:IP 66 (EN60529)
Test:EMC,Low Voltage
Max. Tensite Force:Max. 40 NM
Weight:295 g. for DX-ECAP 101 250mm